Product Description
This is 1500W 48V MPPT BOOST Model with Dump Load and RS232 Communication Port.
1 . Comprehensive introduction of products
1-1 Basic information
Super-intelligent wind/solar hybrid controller is a new type of special high performance control device for new energy application which is designed on the basis of ultra high performance controller. It contains many years of application experience (such as waterproof, dust-proof, salt spray, wiring error, wind resistance limit control of Wind turbines, energy management etc.), it has done to ultimate no matter it applied to the charging control or street light control. In order to meet variety of applications, the controller adopts a hierarchical and modular structure, all functions can be achieved with different functional plates according to actual application, and it is convenient for rapid customization and application.
1-2 Characteristics
Waterproof
Three defenses for circuit board, hierarchical design, even if small amount water enters, it will not damage the device
RS232 communication
Standard configuration RS232 communication, it is easy to do the monitoring with the computer software. (RS485, short-range wireless is optional). Using a USB to RS232 members, more convenient to exchange data with a computer (computer with USB interface can be used).
Safety wire connecting
Terminals are treated with injection molding process, wiring short circuit and cross will not occur, more safety for customers’ operating.
Automatically alarming of battery reverse
Battery input terminal will not be damaged with continuous reverse, and it has buzzer alarm. Avoid equipment damage and fire caused by wiring errors, and better protect the battery.
Automatically alarming of Photovoltaic panels reverse
Photovoltaic panels will not be damaged with continuous reverse, and it has buzzer alarm. It will not cause wiring errors especially when work at night. (Note: reverse connection detection in the night needs manually keys intervention)
Continuous short-circuit output protection
Discharge output terminal has continuous short-circuit protection, and over current protection. It is recovered after the abnormal excluded. Avoid damage of the controller or fire caused by electrical equipment fault (especially the short circuit).
Patented Wind turbines steady speed generation control technology
Patented Wind turbines steady speed generation control method, which makes the Wind turbines not run with super speed, the Wind turbines can keep generation with a limited set speed even in the high winds, avoid direct stop of Wind turbines with over speed caused by strong wind. Greatly improve the Wind turbines generation energy and keep the safe running of the Wind turbines.
Patented Wind turbines stall current limit control technology
Patented Wind turbines stall current limit control methods, which makes Wind turbines not run over current, avoid the damage of expensive generator caused by heating due to over current.
Wind turbines input MPPT generation technology (boost)
Controller can provide automatically Wind turbines input maximum power tracking mode, or the 5 segments match curve input configuration mode(input rev to input current; or output voltage to input current curve), which makes the high efficient generation of the Wind turbines, but with low speed.
Support multiple output mode selection
This controller provides optional multiple output modes (light control, time control, light on in the morning, PWM dimming, reverse direction), which can satisfy a variety of applications.
Statistics the cumulative generating capacity, remaining power, speed, current, temperature and other data
The controller screen displays not only the current, voltage, power of conventional Wind turbines, PV, battery, and the output terminal; but also the cumulative generating capacity of Wind turbines and PV, the remaining battery power, Wind turbines speed, unloading current, and the temperature of controller.
Alarm function when terminals up
When the terminals are up, the controller will alarm, which requires customers to use with the correct install direction, avoid the possibility of damage caused by water comes into the controller when used in the open air or due to bad weather.
2.Product Parameter
HY-T4-WS-10 |
|
Battery parameters |
|
Applied battery voltage |
48V |
Battery protect method |
Reverse connection protection (do not burn any components, with voice prompt); over voltage protection, under voltage protection (for street light and such kind of load) |
Voltage at the over voltage protection point |
58.0V±0.3V |
Voltage at the over voltage recovery point |
55.0V±0.3V |
Voltage at the under voltage protection point |
42.0V±0.3V |
Voltage at the under voltage recovery point |
46.0V±0.3V |
Battery temperature compensation |
5mv/℃/2V (settable) (optional component) |
Wind turbines input parameters |
|
Rated power of applied Wind turbines |
1500W/48V |
Rated power of the terminal |
30A dc (after rectification) |
Max. input current of the terminal |
40A dc (after rectification) |
The default speed of the Wind turbines generation with limited speed |
500 Rpm (settable) |
The default current of the Wind turbines generation with limited current |
30A (settable) |
Wind turbines protection method |
over rev protection, over current protection, induction lightening protection |
Unloading method |
outer unloading device |
MPPT function |
Boost MPPT model ( automatic tracking or 5 segments curve tracking) |
Input current of MPPT channel |
12A |
PV input parameters |
|
Rated input current of applied PV |
1000W/48V(standard) 2000W/48V(optional) |
Rated input current of terminal |
15A(standard) 30A(optional) |
Charging voltage drop |
<0.2V |
PV protection methods |
Reverse connection protection (voice prompt) |
Unloading method |
Open circuit unloading |
Others |
|
Auxiliary function |
Monitor of air temperature inside controller, temperature of unloading parts and Wind turbines MPPT components, and also the monitor of control terminals installed on the inversion (with voice prompt) |
Display mode |
Liquid crystal (LCD) display |
Communication mode |
RS232(5V electrical level) (standard),RS485/ Short-range wireless (optional) |
Displayed parameters |
Wind turbines input voltage/current/power/generated energy/rev/unloading current PV input voltage/current/power/generated energy Battery voltage/charging current/power/total charging capacity/battery status information |
Power consumption in standby mode(screen backlight closed) |
About 20ma /24V system |
Operating mode |
3M foil key operation (4 keys) |
Working temperature / humidity range (environment) |
-40~+80℃/20~85%RH(non condensing) |
Protection grade |
IP41 |
Controller size (L*W*H) |
235mm*148mm *84mm |
Net weight |
2.5KG |
3.Installation process
[SOLAR INPUT]—–Input terminal of solar panel, pay attention to the wiring polarity
[BAT INPUT ]——Input terminal of battery, which is applicable to the 48V level battery, pay attention to the wiring polarity
[WIND INPUT ]—–AC input terminal of the Wind turbines, non-polarity input
Attention: suggest doing wiring according to below order:
1. connect with battery2. connect with solar panel 3. connect with Wind turbines
4 Parameters setting instructions
1. Functions of key
The controller enters into the work standby status ([RUN] words flashing) as soon as it is powered and initialized. The controller displays different information according to the different function types, the specific kind to prevail.
Definintions of the buttons on the panel:
2.LCD screen display
LCD screen can display the following information:
1. Mains electricity supply, displayed when mains electricity exits
2. Wind turbines graph, the graph rotates when the rotate; when brakes, displays brakes box
3. Daytime, night indication symbol. In the daytime displays sun, at night displays moon.
4. Communication display symbol, temporarily retained
5. Battery voltage level symbol, 12V displays 12; 24V displays 24; 48V displays 48
6. Wireless communication display, displays the symbol when has wireless module, displays dynamic symbol during communication
7. The No.1 output status display, when close the output, the symbol not light, otherwise, the symbol light. When short circuit, short circuit symbol displays; when has morning lighting function, and in the state of waiting for morning lighting, light symbol flashing indicates waiting.
8. The No.2 output status display, when close the output, the symbol not light, otherwise, the symbol light. When short circuit, short circuit or over loading and such abnormalities, abnormal symbol displays; when has morning lighting function, and in the state of waiting for morning lighting, light symbol flashing indicates waiting(for normal output). If used LED driver module output, then LED symbol displays
9. Solar MPPT symbol, displays when has solar MPPT components, the symbol flashing when the MPPT works
10. Wind turbines MPPT symbol, displays when has Wind turbines MPPT components, the symbol flashing when the MPPT works
11. PV parameter symbol
Wind turbines parameter symbol
Battery parameter symbol
LED drive output parameter symbol
No.1 output parameter symbol
No.2 output parameter symbol
Temperature symbol
Rev symbol
12. Digital display parameter / status symbol
13. Parameter setting symbol
14. Parameter unit
15. No. 1/2 output/ close status display symbol, displays when has output module, ON corresponding to output open status, OFF to the close status
16. Battery status symbol, displays the rest battery power, after over voltage, displays the over voltage symbol
17. Data checking symbol
We are proud to offer international shipping services that currently operate in over 200 countries and islands world wide. Nothing means more to us than bringing our customers great value and service. We will continue to grow to meet the needs of all our customers, delivering a service beyond all expectation anywhere in the world.
Packages from our warehouse in China will be shipped by ePacket or EMS depending on the weight and size of the product. Packages shipped from our US warehouse are shipped through USPS.
Yes. We provide free shipping to over 200 countries around the world. However, there are some locations we are unable to ship to. If you happen to be located in one of those countries we will contact you.
We are not responsible for any custom fees once the items have shipped. By purchasing our products, you consent that one or more packages may be shipped to you and may get custom fees when they arrive to your country.
Location | *Estimated Shipping Time |
---|---|
United States | 10-20 Business days |
Canada, Europe | 10-20 Business days |
Australia, New Zealand | 10-30 Business days |
Central & South America | 15-30 Business days |
Asia | 10-20 Business days |
Africa | 15-45 Business days |
Yes, you will receive an email once your order ships that contains your tracking information. If you haven’t received tracking info within 5 days, please contact us.
For some shipping companies, it takes 2-5 business days for the tracking information to update on the system. If your order was placed more than 5 business days ago and there is still no information on your tracking number, please contact us.
For logistical reasons, items in the same purchase will sometimes be sent in separate packages, even if you've specified combined shipping.
If you have any other questions, please contact us and we will do our best to help you out.
All orders can be cancelled until they are shipped. If your order has been paid and you need to make a change or cancel an order, you must contact us within 12 hours. Once the packaging and shipping process has started, it can no longer be cancelled.
Your satisfaction is our #1 priority. Therefore, you can request a refund or reshipment for ordered products if:
We do not issue the refund if:
*You can submit refund requests within 15 days after the guaranteed period for delivery (45 days) has expired. You can do it by sending a message on Contact Us page
If you are approved for a refund, then your refund will be processed, and a credit will automatically be applied to your credit card or original method of payment, within 14 days.
If for any reason you would like to exchange your product, perhaps for a different size in clothing. You must contact us first and we will guide you through the steps.
Please do not send your purchase back to us unless we authorise you to do so.